Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Obstet Gynecol ; 143(3): 336-345, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38086052

RESUMEN

OBJECTIVE: To evaluate the performance characteristics of existing screening tools for the prediction of sepsis during antepartum and postpartum readmissions. METHODS: This was a case-control study using electronic health record data obtained between 2016 and 2021 from 67 hospitals for antepartum sepsis admissions and 71 hospitals for postpartum readmissions up to 42 days. Patients in the sepsis case group were matched in a 1:4 ratio to a comparison cohort of patients without sepsis admitted antepartum or postpartum. The following screening criteria were evaluated: the CMQCC (California Maternal Quality Care Collaborative) initial sepsis screen, the non-pregnancy-adjusted SIRS (Systemic Inflammatory Response Syndrome), the MEWC (Maternal Early Warning Criteria), UKOSS (United Kingdom Obstetric Surveillance System) obstetric SIRS, and the MEWT (Maternal Early Warning Trigger Tool). Time periods were divided into early pregnancy (less than 20 weeks of gestation), more than 20 weeks of gestation, early postpartum (less than 3 days postpartum), and late postpartum through 42 days. False-positive screening rates, C-statistics, sensitivity, and specificity were reported for each overall screening tool and each individual criterion. RESULTS: We identified 525 patients with sepsis during an antepartum hospitalization and 728 patients with sepsis during a postpartum readmission. For early pregnancy and more than 3 days postpartum, non-pregnancy-adjusted SIRS had the highest C-statistics (0.78 and 0.83, respectively). For more than 20 weeks of gestation and less than 3 days postpartum, the pregnancy-adjusted sepsis screening tools (CMQCC and UKOSS) had the highest C-statistics (0.87-0.94). The MEWC maintained the highest sensitivity rates during all time periods (81.9-94.4%) but also had the highest false-positive rates (30.4-63.9%). The pregnancy-adjusted sepsis screening tools (CMQCC, UKOSS) had the lowest false-positive rates in all time periods (3.9-10.1%). All tools had the lowest C-statistics in the periods of less than 20 weeks of gestation and more than 3 days postpartum. CONCLUSION: For admissions early in pregnancy and more than 3 days postpartum, non-pregnancy-adjusted sepsis screening tools performed better than pregnancy-adjusted tools. From 20 weeks of gestation through up to 3 days postpartum, using a pregnancy-adjusted sepsis screening tool increased sensitivity and minimized false-positive rates. The overall false-positive rate remained high.


Asunto(s)
Infección Puerperal , Sepsis , Embarazo , Femenino , Humanos , Estudios de Casos y Controles , Periodo Posparto , Hospitalización , Sepsis/diagnóstico , Sepsis/epidemiología , Síndrome de Respuesta Inflamatoria Sistémica , Estudios Retrospectivos
2.
Obstet Gynecol ; 143(3): 326-335, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38086055

RESUMEN

OBJECTIVE: To evaluate the screening performance characteristics of existing tools for the diagnosis of sepsis during delivery admissions. METHODS: This was a case-control study using electronic health record data, including vital signs and laboratory results, for all delivery admissions of patients with sepsis from 59 nationally distributed hospitals. Patients with sepsis were matched by gestational age at delivery in a 1:4 ratio with patients without sepsis to create a comparison group. Patients with chorioamnionitis and sepsis were compared with a complete cohort of patients with chorioamnionitis without sepsis. Multiple screening criteria for sepsis were evaluated: the CMQCC (California Maternal Quality Care Collaborative), SIRS (Systemic Inflammatory Response Syndrome), the MEWC (the Maternal Early Warning Criteria), UKOSS (United Kingdom Obstetric Surveillance System), and the MEWT (Maternal Early Warning Trigger Tool). Sensitivity, false-positive rates, and C-statistics were reported for each screening tool. Analyses were stratified into cohort 1, which excluded patients with chorioamnionitis-endometritis, and cohort 2, which included those patients. RESULTS: Delivery admissions at 59 hospitals were extracted for patients with sepsis. Cohort 1 comprised 647 patients with sepsis, including 228 with end-organ injury, matched with a control group of 2,588 patients without sepsis. Cohort 2 comprised 14,591 patients with chorioamnionitis-endometritis, of whom 1,049 had sepsis and 238 had end-organ injury. In cohort 1, the CMQCC and the UKOSS pregnancy-adjusted criteria had the lowest false-positive rates (6.9% and 9.6%, respectively) and the highest C-statistics (0.92 and 0.91, respectively). Although other screening criteria, such as SIRS and the MEWC, had similar sensitivities, it was at the cost of much higher false-positive rates (21.3% and 38.3%, respectively). In cohort 2, including all patients with chorioamnionitis-endometritis, the highest C-statistics were again for the CMQCC (0.67) and UKOSS (0.64). All screening tools had high false-positive rates, but the false-positive rates for the CMQCC and UKOSS were substantially lower than those for SIRS and the MEWC. CONCLUSION: During delivery admissions, the CMQCC and UKOSS pregnancy-adjusted screening criteria have the lowest false-positive results while maintaining greater than 90% sensitivity rates. Performance of all screening tools was degraded in the setting of chorioamnionitis-endometritis.


Asunto(s)
Corioamnionitis , Endometritis , Sepsis , Embarazo , Femenino , Humanos , Corioamnionitis/diagnóstico , Corioamnionitis/epidemiología , Estudios de Casos y Controles , Estudios Retrospectivos , Sepsis/diagnóstico , Síndrome de Respuesta Inflamatoria Sistémica
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...